Symptoms such as persistent fatigue, a lethargic feeling or irregular digestion may indicate an overloaded liver, a crucial organ that is responsible for detoxifying your blood and storing energy every day. When the liver does not function optimally due to factors such as medication use, diet or lifestyle, this directly affects your overall vitality. With the Swisspoint Care LIVER-Screen self-test, you get quick and reliable insight into your physiological state, so that you can take targeted action for your well-being.
- Direct result within 10 minutes, so you do not have to wait for a laboratory result.
- Reliable detection of elevated transaminase enzymes (ALT and AST) via a simple finger prick.
- User-friendly cassette indicator that displays the result with clear colour zones (red and blue).
- Complete set for home use, including all necessities such as a lancet, pipette and dilution fluid.
How it works
The liver releases specific enzymes, the transaminases ALT and AST, into the bloodstream when there is reduced function or dysfunction. LIVER-Screen® is an immunodiagnostic test specifically designed to detect an increase in this activity in capillary blood. By using an advanced test strip in a cassette, this test offers a scientifically based method to monitor the health status of this essential organ at home.
Composition
| Contents | 1 test kit |
|---|
| Test type | Immunodiagnostic self-test |
|---|
| Detection | Transaminases (ALT / AST) |
|---|
| Sample type | Capillary blood (fingertip) |
|---|
| Weight | 1001.000 kg |
|---|
Ingredients
The test kit contains a test cassette with a reactive strip for the detection of transaminases, a sterile lancet for blood collection, a plastic pipette for sample transfer and a dropper bottle with dilution fluid.
Use & Dosage
1. Prepare the test device, the pipette and the dropper bottle with diluent. Remove them from the protective pouch (tear at the notch. Remove the screw cap from the dilution dropper bottle and leave it nearby).
2. Clean the tip of the middle finger or ring finger with cotton wool moistened with alcohol. Press the lancet firmly against the side of the previously cleaned finger and press the release button.
3. Bring the plastic pipette into contact with the blood sample without pressing the bulb. The whole blood migrates into the pipette by capillarity to the line indicated on the pipette.
4. Dispense the blood into the sample opening of the cassette by pressing down on the bulb of the pipette. Wait 30-40 seconds for the blood to be absorbed. Unscrew the blue cap of the dropper bottle and keep the white cap in place. Add 4 drops of diluent to the well, with an interval of 2-3 seconds. Read the result after 10 minutes. Do not interpret after 15 minutes.
Safety & Disclaimer
Medical device. Read the instructions for use before use. This test is intended as an initial screening and does not replace the professional advice or diagnosis of a doctor. Always consult your GP in case of abnormal results or persistent complaints.